{"product_id":"r-515b-refrigerant-10-lb-virgin-cylinder","title":"R-515B Premium Refrigerant – 10 lb Pure Virgin Grade Cylinder","description":"\u003cdiv class=\"markdown markdown-main-panel md-content enable-luminous-fast-follows enable-updated-hr-color\" id=\"model-response-message-contentr_07bf66abeda53f37\" dir=\"ltr\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv class=\"markdown markdown-main-panel md-content enable-luminous-fast-follows enable-updated-hr-color\" id=\"model-response-message-contentr_c7984e62a9d8095b\" dir=\"ltr\"\u003e\n\u003ch1 data-path-to-node=\"0\"\u003eR-515B Refrigerant (10 lb Cylinder)\u003c\/h1\u003e\n\u003cdiv\u003e\u003ci data-path-to-node=\"1\" data-index-in-node=\"0\"\u003e100% Virgin, Premium-Grade Low-GWP Refrigerant for Centrifugal Chillers\u003c\/i\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eMaintain high-efficiency comfort cooling and support sustainability targets with this \u003cb data-path-to-node=\"2\" data-index-in-node=\"86\"\u003e10 lb factory-sealed cylinder of 100% virgin R-515B refrigerant\u003c\/b\u003e. Engineered specifically as an advanced, lower-GWP alternative for centrifugal chillers, R-515B delivers dependable thermal performance and azeotropic stability for commercial and institutional HVAC applications.\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eWhat's Included\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003e10 lb Factory-Sealed Cylinder:\u003c\/b\u003e Premium, 100% virgin R-515B refrigerant.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eAzeotropic Stability:\u003c\/b\u003e Formulated to maintain consistent composition during operation and servicing, eliminating fractionation concerns.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eA1 Safety Classification:\u003c\/b\u003e Non-flammable, lower toxicity formulation for enhanced operational safety in commercial and institutional environments.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eKey Benefits\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eEco-Conscious Chiller Alternative:\u003c\/b\u003e Delivers a significantly reduced global warming potential compared to legacy high-GWP refrigerants, helping facilities meet modern environmental standards and phase-down schedules.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eDesigned for Centrifugal Chillers:\u003c\/b\u003e Tailored specifically for dependable operation in compatible centrifugal chiller applications, supporting both new servicing requirements and approved retrofits.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eCompact Professional Volume:\u003c\/b\u003e The 10 lb cylinder provides a convenient, manageable capacity for technicians handling specialized top-offs and targeted chiller maintenance work.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eGuaranteed Integrity:\u003c\/b\u003e Factory-sealed packaging ensures clean, uncontaminated product right out of the box.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eImportant Safety \u0026amp; Compliance Guidelines\u003c\/h3\u003e\n\u003cblockquote data-path-to-node=\"10\"\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"10,0\" data-index-in-node=\"0\"\u003eClassification Note:\u003c\/b\u003e R-515B is classified as a non-flammable and lower toxicity (A1) refrigerant, but proper handling and equipment protocols must still be strictly observed.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/blockquote\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eDedicated Use Only:\u003c\/b\u003e Use R-515B exclusively in centrifugal chillers and equipment specifically designed, approved, or properly converted for it. Always verify system and lubricant compatibility prior to charging.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eFor Professionals Only:\u003c\/b\u003e System charging, recovery, installation, leak testing, and servicing must be performed strictly by trained, certified HVAC\/R technicians following manufacturer guidelines.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eRegulatory Compliance:\u003c\/b\u003e As a fluorinated greenhouse gas, R-515B may be subject to local, state, or federal phase-down rules, sales restrictions, and handling mandates. Verify all applicable regulations in your jurisdiction prior to purchase and use.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"techchillsupply","offers":[{"title":"Default Title","offer_id":67585605108077,"sku":"0","price":120.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1032\/3568\/2669\/files\/r515b_2793b3dd-4458-4871-9b0b-9910c4adcce5.jpg?v=1790730007","url":"https:\/\/frostpeaksupply.shop\/products\/r-515b-refrigerant-10-lb-virgin-cylinder","provider":"My Store","version":"1.0","type":"link"}